Commissioning and Diagnostics of Power Transformers

19 - 22 septembre 2024
Royaume-Uni (Stafford)
Anglais
Cptr06en
DIRANA, TESTRANO 600, Primary Test Manager (PTM), FRANEO 800, Famille de produit CPC

Résumé

After an introduction of selective measurements to perform on power transformers, you will develop your skills through theoretical and practical sessions performing conventional and diagnostic tests with CPC 100 or TESTRANO along with the CP TD1. Furthermore, you will learn how to perform reliable Sweep Frequency Response Analysis (SFRA) measurements to detect winding deformation with FRANEO 800 and to use DIRANA to perform dielectric response measurements and determine the moisture content in oil-paper insulated power transformers.

Objectifs

  • Overview of the structure of the power transformer, core, insulation, windings, bushings and the tap-changer
  • Analysis of the condition of power transformers to fully exploit the lifetime of your asset
  • Carry out time-optimized tests and diagnostics in our workshop
  • Preparing and performing SFRA measurements on power transformers
  • Using DIRANA to measure the dielectric response on power transformers and determine the moisture content
  • Applying the Primary Test Manager (PTM) software as support tool for the entire measurement process
  •  

Contenu

  • Introduction to power transformer commissioning, maintenance, condition assessment and diagnostics 
  • Theoretical background and performance of ratio, excitation current, vector group, winding resistance, short circuit impedance measurements and demagnetization of the transformer
  • Theoretical background and performance of capacitance & power/dissipation factor (tan delta) tests on power transformers and bushings 
  • Basics and theory to understand the SFRA measurement method and connection techniques
  • Influences on the reproducibility of an SFRA measurement trace
  • Measurement of the dielectric response of power transformers
  • Understand the causes of the ageing of cellulose and insulation oil
  • Analysis of dielectric response curves
  • Sources of moisture in transformers
  • Interpretation of test results
  • A new approach to facilitated power transformer testing with a software tool (PTM) for intuitive power transformer testing and reporting
  •  

Horaire

Day 1: 08:45 a.m. - 05:30 p.m.

Day 2: 09:00 a.m. - 05:30 p.m.

Day 3: 09:00 a.m. - 04:00 p.m.

Information

You will receive a personal email with all course information such as agenda and route directions shortly before the training course.

You can select your desired hotel from our hotel recommendations in UK Training Center83 kB and book it directly according to your preferences.

Public

Technical staff from utilities or companies working mainly in commissioning or maintenance testing of power transformers.

Prérequis

Basic knowledge of Power Transformers

Solutions

CPC 100 
CP TD1
CP SB1
TESTRANO 600
FRANEO 800
DIRANA
Primary Test Manager (PTM)

GBP 2 040
par personne, hors taxes
Fully Booked
Etre mis en liste d'attente

„Ce qui m’a vraiment impressionné, c’était la flexibilité du formateur pour répondre aux questions avec une méthode adaptée à chaque personne.“

Commentaire de participant

Nos formations vous permettront de vous familiariser avec les équipements et les applications des réseaux électriques. 

Savoir-faire applicatif

Profitez d’un mélange efficace de présentations des équipements, de connaissances théoriques et de tests pratiques.

Méthodes de formation efficaces

Vos applications particulières sont discutées pendant la formation. Les participants pourront poser les questions propres à leurs 

applications. 

Discussions approfondies
Vous utilisez une ancienne version de votre navigateur.
Merci de mettre à jour votre navigateur ou d’utiliser un autre navigateur pour afficher cette page correctement.
×